TERRACON
QUALITÄT ALS FUNDAMENT |
 |
| VIBRO-PILES AND VIBRO-COMBI-PILES |
 |
|
The Vibro-pile is a driven cast-in-situ pile, which is very competitive to
the precast concrete-pile in the larger dimensions. The Vibro-pile offers an advantage,
as the construction time is not at the mercy of possible prefabrication and curing
time. Even the design needs little preparation. When a design is being changed,
pile quantities as well as lengths and diameters can be adapted fairly easily.
Vibro-piles are especially suitable when hard layers need to be penetrated and/
or when soil conditions lead to a variety of pile toe levels. In combination with
a pre-stressed concrete core with high tension, a system such as Vibro-combi-pile
is especially suitable. Amongst other applications are the construction of floors
which are subject to driving stress like tunnels, basements, etc. As well as tension/
pressure piles in water or extremely soft compressible layers. |
 |
| The TERR-ECON-PILE can be executed in
three varieties: |
 |
| • |
Cast-in-situ Terr-Econ-pile by which the casing is extracted; |
| • |
Terr-Econ-casing-pile by which the casing stays permanently behind; |
| • |
Terr-Econ-casing-pile with “mixed in place” cement mortar by which
drilling in compact layers will be easier and the positive skin friction will
enlarge considerably (larger diameter and a higher friction level). Cement is
pumped during the drilling process to the pile toe where it is mixed in the layers
with bearing capacity to a “mixed-in-place” mortar covering the tube. |
|
 |
| TERR-ECON-DRILLING-PILES (soil displacing,
vibration free cast-in-situ piles) |
 |
|
Terracon has drilling tables available with a high torque moment. In combination
with vertical pull-down on the drilling case, piles can be placed vibration free
and soil displaced. Even in high resistant layers high bearing capacity can be
realised. Due to the “top-drive” drill table, piles can be drilled
quickly, efficiently and ECONomically. |
 |
| TERRA-COMBI-PILES (anti-negative skin
friction) |
 |
|
Terracon has developed a method to neutralise, for the most part, the possible
appearance of negative skin friction alongside the pile shaft. The Terra-combi-pile
consists of a precast core which is being covered with grout down to layers contributing
positive skin friction. Whereas in layers where negative skin friction appears,
bentonite is the lubricant to reduce this negative skin friction. Because a high
net bearing ability is being reached, an economical solution is possible. This
system can be drilled in place and is vibration free as well. |
 |
| TERRA-CONCRETE-WALL (drilled, cast-in-situ
concrete wall) |
 |
|
The Terra-concrete-wall is a cast-in-situ concrete wall, by which two hollow
steel panels are used with a right-angled cross-section, which serve as a temporary
casing. The Terra-concrete-wall can be applied as permanent retaining wall for
basements, tunnels, underground parking garages, depots for contaminated and/
or aggressive soils, manure depots, liquid reservoirs, deep construction of roads
and railways, as well as lost excavated building-site limitation (instead of a
steel diaphragm wall). The wall can function in the construction as a lost outside
formwork of a concrete-wall or as possible formwork for sprayed concrete or brickwork.
Terracon can also take care of the complete supply and installation of:
|
| – |
sheet walls, diaphragm walls and pile walls; |
| – |
slurry walls: liquid closed walls of bentonite or bentonite cement, and if
necessary soil mixing; |
| – |
complete excavated building-sites, if necessary with compaction and/ or anchoring; |
| – |
jet-grouting, freezing and soil injections; |
| – |
piles in limited height and space. |
|
 |
| TERRA-SON-DRILLING-PILES (screwed piles
with precast core) |
 |
|
Terracon has developed in co-operation with Beton Son B.V. a vibration free
and for the most part cast-in-situ pile. It consists of a vibration free placed
precast pile, which is covered with mortar down to the positive skin friction
contributed layers. The pile shaft produced with a high quality concrete (B55)
is utilised optimally, is economical, qualitative eminent and is an eco-friendly
foundation system. Due to high pre-stress the pile is extremely suitable as a
tension pile. |
 |
| MV-TENSION PILES (steel piles with mortar/
grout) |
 |
|
Terracon has specialised itself in manufacturing tension piles with high bearing
capacity which can be applied to power pylons, foundation of embankment walls,
docks, floors subject to driving stress, wind mills- and transmitter mast foundations,
etc. For this purpose tubes or steel profiles are covered with mortar during drilling
(or boring). Bearing capacities of 500 kN to 2500 kN have been realised. For steel
tube masts (such as advertisement masts, transmitter masts etc.) steel tube pipes
with a diameter up to 2200 mm can be offered. |
 |
| EQUIPMENT |
 |
| Terracon possesses a range of very modern equipment including: |
| • |
piling rigs able to work up to 1:1 backward rake (piling away
from the rig) and side rake of 1:5 with quick on site erection and dismantling,
which may be converted from pile driving to pile drilling techniques; |
| • |
piling rigs with leaders of 55 m length to suit piles of up to 45 m in length; |
| • |
hydraulic piling hammers being soundproof and eco-friendly. Computer and printer
monitor the complete driving process. The driving performance is controlled by
an adjustable energy level; |
| • |
very high torque hydraulic rotary heads. The complete drilling process is
monitored by computer and printer, recording torque speed, torque moment, etc.; |
| • |
grout pumps for grout injection of MV-piles and Terra-Son-piles; |
| • |
mixers, which can be operated either stationary or mobile on caterpillar tracks
to reach parts of the construction site with difficult access; |
| • |
TNO integrity tester for ultrasonic measurement of cast-in-situ piles; |
| • |
pile testing rig on caterpillar tracks for tension piles up to 3000 kN capacity. |
|
 |
| WOULD YOU LIKE MORE INFORMATION??? |
 |
|
In order to discuss and explain the possibilities in detail, we will be happy
to make an appointment with you. With our experience and engineering, we are in
the position to offer you a qualitative, well-thought out and economically attractive
solution. |
 |
Terracon Funderingstechniek B.V.
Vierlinghstraat 17
P.O.Box 49
4250 DA Werkendam
The Netherlands |
Terracon International B.V.
Telephone +31 (0) 183 403529
Telefax +31 (0) 183 403583
E-mail info@terracon.nl
Trade register 18.047.657 |
|